Version |
Date |
Change
Item |
7.038 |
3/2005 |
|
7.036 |
1/2004 |
|
7.035 |
10/2003 |
|
7.034 |
2/2003 |
|
| |
7.032
 |
3/2002 |
- Ability to continuously scan for continuity
versus in a specific order
- Ability to force a restart of a test
when a harness has been prematurely removed, insuring that the next harness is
fully tested
- Added Dyna-IR infrared protocol
- Improved the robustness of IrDA infrared
protocol
- Changed the LINE4 sequence command
to allow format symbols
- Allowed for constant test width when
using the |E and |F format symbols
|
|
7.020
 |
4/2001 |
- InfraRed menus and functionality
greatly improved
|
|
7.012
 |
1/2001 |
- SCOUNT and RCOUNT counters
can now be set to maximum value of 65535
|
|
7.011
 |
12/2000 |
- Changes made to enhance
infrared transfers and to more fully meet the IrDA specifications
|
|
7.010
 |
11/2000 |
- Changed IR transfer protocol
to meet IrDA specification
- Added driver to support
external display for viewing messages from the Message table
- Serial port device menus
and functionality improved
|
|
7.002
 |
10/2000 |
- New serial port device
menus support IR Data Transfer Modules (Part No. 212-5000) and Adaptive Model
213C-1 (Beta Brite Display)
- Key setup function bug
fixed
|
|
7.001
 |
4/2000 |
- Added ability to print
Julian Date Code on a label
- Infrared communication
protocol enhanced
- Configuration Menu split
into two menus - Restrictions Menu and the Configurations Menu
- Serial Port Timeout setting
has been changed to allow settings in 10ms increments
|
|
7.000
 |
1/2000 |
- New 1MB EPROM used -
requires new IC component (Part# 5280184)
- Added SWITCH-RANDOM command
to perform random order switch test
- AUTOLEARN capability
enhanced to allow other programs to be used as templates for learned programs
- includes Test Parameters, Symbolic Names, ALARM Netlist, Sequence, and Messages
- AUTOLEARN Rename functionality
added
|
|
6.001
 |
9/1999 |
-
Eliminated intermittent Soft Short error associated with
harness lengths or capacitance in the harness
-
Eliminated AUTOLEARNED program errors associated with
long harness lengths or capacitance in the harness
|
|
6.000
 |
9/1999 |
-
Analyzer error message now displays both color and wire information
-
Detection Switch errors now display "SWITCH OPEN" and
"SWITCH CLOSED" versus "OPEN" and "SHORT"
-
Probe Mode now displays "CONNECTED" when the probe is
touching a connection to a Test Point
-
Errors associated with splices are now displayed as "OPEN (Splice 3)"
versus "3 OPEN"
-
Renamed Error Tone menu from "LOUD/SOFT" to "LONG/SHORT"
-
Added capability to allow Analyzer to operate as a InfraRed
print server
-
Miswire functionality added that performs a background
Short Scan while the Analyzer is stopped on an OPEN error; if either of the
two open points are shorted elsewhere, a MISWIRE ERROR will occur
-
Sample Tones added for Error Tones menu
-
Disabled ability to advance past the AUTO command by
pressing the START button
-
RUN Sequence command added that is used to
execute another program that is loaded in the Analyzer's memory
-
Added ability to print a sample label directly from the Analyzer
-
BKEY command added to allow a branch to a specific
line number if the keyswitch is closed
-
CLEARVARS command added that will clear all of the
variables in memory
-
Error Log enhanced to produce a warning message
when the log is full
-
Reset Option added if errors are found during the Test
Point test
-
Overwrite File warning added when transferring data
from a DynaCard
-
Automatic Restart option added that would restart
the previously loaded program on Address Exception Errors
|
|
5.100
 |
5/1999 |
- Menu structure
enhanced to provide better descriptions and navigation Analyzer menus
- Error Log enhanced to
display the amount of memory allocated when exiting the display
- Control Port Bit Test
modified to display the number of the bit currently being tested
- AUTO command
enhanced to allow the entire Netlist to be scanned
- Checksum added to an
AUTOLEARNED program
-
Diode test enhanced to look for 10 consecutive matching results for a valid test
|
|
5.022 |
3/1999 |
- AUTOLEARN checksum
algorithm enhanced
|
|
5.021 |
2/1999 |
- 256XL XBIT protocol
added to allow the 256XL to access old PDC boards as well as I/O Extension
System boards
- Control Port SPI
protocol added to allow use of I/O Extension System boards
- X-Modem protocol
enhanced to recognize CRC and checksum modes
- Checksum feature
added to prevent corruption of .BIN files
- Parameter functions
enhanced to store the parameter values in a temporary location, not in the .BIN file
|
|
5.020 |
9/1998 |
- Pushbutton Debounce
function added
- Alarm function
enhanced; Analyzer looks for a change of state of the keyswitch, either
on-to-off or off-to-on, instead of just off
- Serial Port Timeout
feature added; if no response is detected from the receiving device
within the specified timeout period, the Analyzer will display the message
"SERIAL 2 TIMEOUT" and move to the next Sequence command
|
|
5.019 |
7/1998 |
- Boot-up time reduced
to one (1) second
- Serial Ports enhanced
to allow use of 38400 baud communication rate
- Serial Port Timeout
enhanced to use a counter instead of the real time clock
- SERIAL1 and SERIAL2
commands added for enhanced control of the Analyzer's serial ports
|
|
5.018 |
6/1998 |
|
|
5.017 |
6/1998 |
- Modified the ALARM
macro to maintain compatibility with ALARMOFF sequence macro
|
|
5.016 |
3/1998 |
- Download Memory
Available message; now displays the total memory available in the destination
memory
- Power-Up Scan
diagnostics test enhanced
- Probe function display
enhanced to show both symbolic information and absolute Test Point on the
same display for each point probed
- Spanish text added for
menus and error messages
- ALARM_BIT function
added to the MENUS>OTHER menu
|
|
5.015 |
2/1998 |
- "Insufficient Points"
message now includes the number of points present
- New sounds added;
10- low/high/low, 11- high/low/high, 12- fog horn, 13- charge
- BBRK command added
to branch to a specified sequence line when the Break flag is set
- SCANBRK command
added to scan a specified Netlist when the Analyzer stops on an error
- Last Errors variables
added for label printing Alarm Key flag enhanced; the STOP button is only
deactivated if the Key flag in enabled
- ALARM function
enhanced so that only the key can turn the alarm off
- Moved UNIT_ID
Function to SETTINGS: MORE menu
- Verification procedure
added when writing data to the cartridge
|
|
5.014 |
7/1997 |
- ADVON Cartridge
feature enhanced in conjunction with the ADVOFF Sequence command
- Changed the Manual
Advance Flag to be enabled at the start of every Sequence or after every
REPEAT command
|
|
5.013 |
7/1997 |
- Error Logging
functionality enhanced
|
|
5.012 |
5/1997 |
- Capacitor Testing
functionality enhanced
- Error Logging
functionality enhanced
|
|
5.011 |
5/1997 |
- TESTTIME, TIMESTART
and TIMESTOP commands added
- CAP and PCAP Netlist
commands added to test capacitors and polarized capacitors
- BST (Branch On Start
Key) command added that checks the status of the start button
- SYNCHI and SYNCHLO
commands added
- Manual Advance Flag
default changed to disabled
- ADVON (Advance On)
cartridge feature added to work in conjunction with the Manual Advance Flag
|
|
5.010 |
2/1997 |
- ALARM functionality added
|